AHU Services

AHU Frost Coil Fault in London & the M25

Frost coil fault diagnosis covering the frost stat, pre-heat sequence, flow and damper strategy so the coil is protected on cold nights.

REFCOM & F-Gas certified24/7 emergency callout£120+VAT/hr · 1 hr minimum

AHU Frost Coil Fault explained

Frost coil fault diagnosis covering the frost stat, pre-heat sequence, flow and damper strategy so the coil is protected on cold nights.

  • Frost stat capillary position and setting: Confirm the component identity and model-specific requirements before deciding whether adjustment, testing or replacement is appropriate.
  • LPHW flow, valve and pump operation: Check movement, control command and the effect on flow together; the actuator and valve body can fail independently.
  • Pre-heat sequence and shutdown strategy: Confirm the component identity and model-specific requirements before deciding whether adjustment, testing or replacement is appropriate.
  • Glycol strength where applicable: Confirm the component identity and model-specific requirements before deciding whether adjustment, testing or replacement is appropriate.
  • Damper closure on shutdown: Check movement, control command and the effect on flow together; the actuator and valve body can fail independently.
  • Winter protection recommendations: Confirm the component identity and model-specific requirements before deciding whether adjustment, testing or replacement is appropriate.

Interpreting the reported fault

Inspect filters, belts or direct drives, dampers, coils and control response. Airflow limitations may be mechanical or arise from the control strategy.

  • Reported symptom: frost stat trips in cold weather or fear of a burst coil overnight

AHU Frost Coil Fault: scope and decisions

Air handling and ventilation concern delivered airflow as well as fan operation. A motor running does not establish adequate supply or extract at the occupied space.

Fan upgrades need the required duty and compatibility checked. Replacing a motor alone will not correct excessive system resistance, failed dampers or an unsuitable operating schedule.

Provide the unit model, symptoms, filter records and safe access arrangements. Explain whether the issue is noise, reduced flow, temperature or loss of extract.

Agreeing a diagnostic visit

A diagnostic visit is paid time to find the cause. Expect the readings taken and a clear statement of the fault, with any repair quoted before work continues.

  • The readings and tests to be carried out
  • A written finding
  • Repair price before further work

Engineer labour is £120 + VAT per hour with a one-hour minimum; parts and refrigerant are quoted in writing before they are fitted.

How each type of visit works and all rates · What to have ready when you book · How we work