AHU Services

AHU Repair in London & the M25

AHU repair across fans, drives, coils, dampers and controls, with the fault history reviewed so recurring problems are dealt with properly.

REFCOM & F-Gas certified24/7 emergency callout£120+VAT/hr · 1 hr minimum

AHU Repair explained

AHU repair across fans, drives, coils, dampers and controls, with the fault history reviewed so recurring problems are dealt with properly.

  • Fault and alarm history review: Confirm the component identity and model-specific requirements before deciding whether adjustment, testing or replacement is appropriate.
  • Fan, motor and drive testing: Operation, mechanical condition and control demand must be separated before condemning the drive.
  • Belt, bearing and coupling condition: Operation, mechanical condition and control demand must be separated before condemning the drive.
  • Coil, damper and actuator checks: Condition and airflow affect heat transfer; look beyond surface appearance to obstruction and operating performance.
  • Electrical and isolator inspection: Electrical tests and isolation belong to a qualified person; repeated resetting should not replace fault investigation.
  • Repair report with remedial options: Confirm the component identity and model-specific requirements before deciding whether adjustment, testing or replacement is appropriate.

Interpreting the reported fault

Inspect filters, belts or direct drives, dampers, coils and control response. Airflow limitations may be mechanical or arise from the control strategy.

  • Reported symptom: noise, vibration, no supply air or a unit tripping out

AHU Repair: scope and decisions

Air handling and ventilation concern delivered airflow as well as fan operation. A motor running does not establish adequate supply or extract at the occupied space.

Fan upgrades need the required duty and compatibility checked. Replacing a motor alone will not correct excessive system resistance, failed dampers or an unsuitable operating schedule.

Provide the unit model, symptoms, filter records and safe access arrangements. Explain whether the issue is noise, reduced flow, temperature or loss of extract.

Agreeing the repair

A repair visit starts by confirming the fault and its cause, so the part replaced is the one that failed. The repair finishes with a test under normal operating load.

  • The component found at fault and why it failed
  • Parts, refrigerant and lead time in writing
  • The test that proves the repair worked

Engineer labour is £120 + VAT per hour with a one-hour minimum; parts and refrigerant are quoted in writing before they are fitted.

How each type of visit works and all rates · What to have ready when you book · How we work