Commercial refrigeration keeps chilled and frozen stock inside safe temperature limits from delivery to sale. We install, repair and maintain refrigeration for restaurants, pubs, hotels, supermarkets, convenience stores, food production, laboratories and healthcare sites across London and the M25. Our F-Gas certified engineers work on cold rooms, walk-in freezers, upright and undercounter fridges, display cabinets, blast chillers, cellar cooling and ice machines, along with the condensing units, evaporators, controls and refrigerant pipework that serve them. This page is the starting point for every refrigeration service we offer, so you can go straight to the page that matches your equipment or fault.

Call 07414 254125

Engineer labour from £120+VAT/hour · One-hour minimum · 24/7 breakdown line · Parts quoted in writing first

Commercial refrigeration installation

A new installation starts with a site survey. The engineer records the room or cabinet size, the product load, how often doors open, the ambient temperature where the condensing unit will sit and the electrical supply available. Those figures set the cooling duty, so the plant is neither undersized and running continuously nor oversized and short cycling.

Installation covers siting the condensing unit and evaporator, running and brazing refrigerant pipework under a nitrogen purge, condensate drainage, electrical connection and the controller. Before any refrigerant goes in, the system is pressure tested with oxygen-free nitrogen and evacuated to a deep vacuum to remove moisture and air. It is then charged, the superheat and pressures are checked against the manufacturer's figures, alarms are set and the handover pack, including the F-Gas record, is left with the site.

Repair and breakdown response

Most refrigeration breakdowns show up as a cabinet or room running warm, ice building on the evaporator, water on the floor, a compressor tripping or a temperature alarm. The engineer works from evidence: suction and discharge pressures, superheat and subcooling, controller history, probe readings and the electrical condition of the compressor and fans. That separates a blocked condenser or failed defrost from a refrigerant leak or a worn compressor, so the repair fixes the cause rather than the symptom.

Common parts such as fan motors, probes, contactors, door seals and controllers are carried on the van. Where a compressor, expansion valve or coil has to be ordered, you get a written quote before any chargeable part is fitted. The 24/7 emergency line covers breakdowns where stock or trading is at risk, and the first aim is always to restore cooling safely and protect product.

Planned maintenance

Planned maintenance is the most reliable way to cut breakdowns. A typical visit cleans the condenser coil, checks the evaporator and defrost, tests door seals and heaters, inspects electrical connections, verifies probe accuracy against a calibrated thermometer and logs pressures and temperatures. Comparing those readings visit by visit shows a slow leak or a tiring compressor before it becomes an emergency.

Visit frequency depends on the duty. A busy kitchen with fridges beside cooking lines, or a cellar cooler in a hot plant space, usually needs more frequent condenser cleaning than a cold room in a cool, clean area. Each visit ends with a written report listing anything that needs attention, so you can plan work rather than react to it.

F-Gas compliance and refrigerant handling

Refrigeration systems above the F-Gas thresholds need periodic leak checks, and every addition or recovery of refrigerant has to be recorded. Our engineers are F-Gas certified and the company is REFCOM registered, so leak checks, recovery and recharging are carried out and logged correctly. We work with common commercial refrigerants including R404A, R449A, R452A, R448A, R134a, R513A and R290, and can advise where an older high-GWP system is better retrofitted or replaced.

Leaks are found with electronic detection, bubble testing and, where needed, a nitrogen pressure test of an isolated section. A leak is repaired before the system is recharged; topping up a leaking system without finding the leak only repeats the breakdown.

Choosing the right equipment and page

Each type of refrigeration has its own common faults. Cold rooms and walk-in freezers usually fail through iced evaporators, door heater and seal problems, or condensing units struggling in hot plant spaces. Upright and undercounter fridges in kitchens suffer from blocked condensers, worn door gaskets and failed fan motors. Display cabinets depend on airflow across the shelves, so blocked return grilles and dirty coils show up first as warm product at the front. Cellar coolers run hard through summer and need clean condensers and working drains. Ice machines are sensitive to water quality and scale, so cleaning and descaling matter as much as refrigeration repairs.

The service list below groups every refrigeration page on this site by equipment and by type of work, from installation and servicing to fault finding, refrigerant handling and brand-specific repairs. If you are not sure which applies, call the engineer line and describe what the equipment is doing; the engineer will tell you what to check and whether a visit is needed.

Prices and how we quote

Engineer labour is £120 plus VAT per hour with a one-hour minimum. Parts, refrigerant and complete installations are quoted in writing after the engineer has seen the equipment, so you know the cost before work goes ahead. Planned maintenance is quoted from the number and type of units on site.

All commercial refrigeration services

See also our prices and all HVAC services.

Commercial refrigeration questions

Engineer labour is £120 plus VAT per hour with a one-hour minimum. Parts and refrigerant are quoted in writing before they are fitted.

Yes. Our 24/7 emergency line on 07414 254125 covers commercial refrigeration breakdowns where stock or trading is at risk across London and the M25.

Yes. Our engineers are F-Gas certified and the company is REFCOM registered, so refrigerant leak checks, recovery and charging are carried out and recorded correctly.

Cold rooms, walk-in freezers, commercial fridges and freezers, display cabinets, blast chillers, cellar coolers, ice machines and the condensing units and controls that serve them.

It depends on duty and location. Equipment in hot kitchens or plant spaces usually needs more frequent condenser cleaning; the engineer recommends a frequency after the first visit.